Skip to product information
1 of 3

Freskool

Low-Temperature Condensing Units (2–8 HP)

Commercial refrigeration equipment is selected around the application—not cart quantity.
Share your project conditions and our team can help confirm the appropriate product family and configuration.
View full details

CONDENSING UNITS · LOW TEMPERATURE

For walk-in freezers and commercial subfreezing applications

Air-cooled 2–8 HP condensing-unit family for low-temperature refrigeration systems. Confirm refrigeration load, evaporating condition, design ambient, refrigerant, voltage and the matching unit cooler before selecting the model.

PRODUCT GALLERY

See every size from every angle

Compare representative 2 HP, 5 HP and 8 HP configurations visually before reviewing final model-specific engineering data.

Freskool 2 HP condensing unit front three-quarter view
Freskool 5 HP condensing unit front three-quarter view
Freskool 8 HP condensing unit front three-quarter view

ENGINEERING & MANUFACTURING DETAILS

More than a front view

See the coil, connections, labeling and construction details that matter during selection, installation and service.

Freskool condensing unit brand and cabinet detail Freskool blue heat exchanger coil detail Freskool warning and product label detail Freskool heat exchanger protection grid detail Freskool heat exchanger fin detail Freskool copper service connection detail Freskool refrigerant connection close-up Freskool condensing unit product lineup

UPDATED TECHNICAL DATA

Selection Data & Operating Envelope

Engineering data by product family. Confirm final selection with Freskool against actual project conditions.

Ambient temperature-4°F to 120°F
Room temperature-13°F to 14°F
RefrigerantsR448A / R449A / R404A
Power supply208–230V / 3PH / 60Hz
ModelHPCompressorDisplacementFanNet weight
BGL22-050A2ZF06KQE-TF55.9 m³/h1 × 500 mm90 kg
BGL22-075A3ZF09KQE-TF58.6 m³/h1 × 500 mm90 kg
BGL22-125A5ZF15KQE-TF514.4 m³/h2 × 500 mm137 kg
BGL22-150A6ZF18KQE-TF517.2 m³/h2 × 500 mm137 kg
BGL22-200A8ZF24KQE-TF521.4 m³/h2 × 500 mm143 kg

Note: Capacity varies with evaporating and ambient conditions. Request engineering selection to confirm the model and operating point.

COMMERCIAL REFRIGERATION · PROJECT-BASED SELECTION

Engineering Selection Overview

This Freskool product family is designed for walk-in freezers and low-temperature cold storage. Selection starts with actual project conditions and should be confirmed against current model-specific engineering data.

Typical application

Walk-in freezers and low-temperature cold storage

System role

Condensing-side equipment for a matched commercial refrigeration system.

Selection basis

Load, temperature, ambient, refrigerant, voltage and site conditions.

BEFORE SELECTING A MODEL

Confirm the project conditions

  • Target room temperature and evaporating conditions
  • Calculated refrigeration load or required capacity
  • Outdoor design ambient and installation environment
  • Refrigerant and applicable regulatory requirements
  • Electrical service and voltage
  • Line length, piping layout, mounting and site conditions

For this 2–8 HP family, final model selection should be based on design load and operating conditions rather than horsepower alone.

SELECT AS A SYSTEM

Pair the right components

A commercial refrigeration installation should be selected as a system, not as isolated components. Review the complementary Freskool family and verify the final match against current engineering data.

View complementary product family Walk-In Freezer Guide

TECHNICAL RESOURCES

Need model-specific engineering data?

Request current performance, electrical, refrigerant-compatibility and available technical documentation for your project conditions.

DIRECT PROJECT ANSWERS

Common selection questions

What is this Freskool product used for?

This Freskool product family is designed for walk-in freezers and low-temperature cold storage. Selection starts with actual project conditions and should be confirmed against current model-specific engineering data.

How do I select the correct model?

Confirm target temperature, refrigeration load, design ambient, refrigerant, voltage and site conditions. Final selection should be reviewed against current model-specific engineering data.

Can I select only by horsepower or room size?

No. Horsepower and room size are only part of the selection. Product load, infiltration, ambient, temperature, refrigerant, piping, controls and actual use also affect the required configuration.

Can Freskool help match a condensing unit and unit cooler?

Yes. Share the project conditions so the appropriate product-family combination can be reviewed. Final matching should be confirmed against current engineering data.

Where can I request current technical data?

Use Technical Resources or Request Engineering Selection to ask for available capacity, electrical, refrigerant-compatibility and current model documentation.

NEXT STEP